One or more zone lights will light up indicating what service is required. If the service light is on press the * key followed by the 2 key to determine the service condition. The service light will be on if the security system requires service.

caddx nx6 user manual

Identifying Service or Trouble Conditions The zone # that is lit indicates the digit of the code (for 9 zones 1 & 8 will be lit).įlashing power light means low battery. Press Enter user # (3 digit # for NX-8E) Press the down arrow (press the arrow 4 times to see all 4 digits of the user code) and the zone LED’s will light up. To bypass a zone press the Bypass key then the zone number then the Bypass key twice If the chime is off the CHIME light will be off. If the chime is on the CHIME light will be on. The door chime is turned on or off by pressing the CHIME key while the system is in the disarmed state. ** Do NOT delete user 1 Activating the Chime Mode: To Delete a user code enter **** for a 4 digit code after step 3. To delete a user code enter **** for a 4 digit code after step 3. Step 5 – Press the # key while the ready light is flashing to exit the User Code Programming Mode.

caddx nx6 user manual

Step 4 – Enter the new 4 digit user code. Step 3 – Enter the 2 digit “user number” (example: 01 for user #1 if changing Master Code.) Step 1 – Press *5 and the Master Code (main user code). System must be disarmed to change user codes Interlogix NX-4 NetworX 4 Zone Control Panel Changing and Adding User Codes NX-4, NX-6, or NX-8

  • interlogix NX-4 NetworX 4 Zone Control Panel User Guide.
  • Search for your system below, then click on the link to download a PDF of that user manual.
  • NICET Certified Engineers & Technicians.
  • Tennessee Licensed Low Voltage Contractor E-D Classification.
  • Tennessee Licensed Burglar Alarm Contractor.
  • Tennessee Licensed Access Control Contractor.
  • Tennessee Licensed Fire Alarm Contractor.
  • caddx nx6 user manual

    Alpha Hospital Communications Equipment (Nurse Call).We also offer design, sales, service and installation of other lines: GE – Tru Portal Security Platform – Access Control.Qualification SafeT is a Factory Authorized Distributor for the following manufactures: SafeT Systems employs a diversified technical project management staff, with over 50 years collective experience in the fire alarm and low voltage control system industry.OnQ Systems – Voice, Data, Video, Controlįiber Optic Cabling Installation and Certification | CATV and MATV Private Cable TV Systems.Apartment / High-Rise Tele-Entry Systems.Surveillance Cameras – Closed Circuit Television Systems Exclusive Dealer for Siemens SINORIX Clean Agent Suppression Systems.System Certification (NPFA-72)(UL – Underwriters Laboratories).Testing & Inspection (NFPA-72 Chapter 10).Exclusive Dealer for state-of-the-art Siemens Fire Detection Systems.









    Caddx nx6 user manual